Electromagnetic compatibility (EMC) design and test case analysis (Record no. 1779)

MARC details
000 -LEADER
fixed length control field 03327nam a22001817a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220907162023.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220907b |||||||| |||| 00| 0 eng d
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number 9781118956823
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 621.38
Item number ZHE
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Junqi Zheng
245 ## - TITLE STATEMENT
Title Electromagnetic compatibility (EMC) design and test case analysis
Statement of responsibility, etc. Junqi Zheng
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Singapore,
Name of publisher, distributor, etc. Wiley
Date of publication, distribution, etc. 2019
300 ## - PHYSICAL DESCRIPTION
Page number 473p:
505 ## - FORMATTED CONTENTS NOTE
Formatted contents note Intro; Title Page; Copyright Page; Contents; Preface; Exordium; Introduction; Chapter 1 The EMC Basic Knowledge and the Essence of the EMC Test; 1.1 What Is EMC?; 1.2 Conduction, Radiation, and Transient; 1.3 Theoretical Basis; 1.3.1 Time Domain and Frequency Domain; 1.3.2 The Concept of the Unit for Electromagnetic Disturbance, dB; 1.3.3 The True Meaning of Decibel; 1.3.4 Electric Field, Magnetic Field, and Antennas; 1.3.5 Resonance of the RLC Circuit; 1.4 Common Mode and Differential Mode in the EMC Domain; 1.5 Essence of the EMC Test; 1.5.1 Essence of the Radiated Emission Test 1.5.2 Essence of the Conducted Emission Test1.5.3 Essence of the ESD Immunity Test; 1.5.4 Essence of the Radiated Immunity Test; 1.5.5 Essence of the Common-Mode Conducted Immunity Test; 1.5.6 Essence of the Differential-Mode Conducted Immunity Test; 1.5.7 Differential-Mode and Common-Mode Hybrid Conducted Immunity Test; Chapter 2 Architecture, Shielding, and Grounding Versus EMC of the Product; 2.1 Introduction; 2.1.1 Architecture Versus EMC of the Product; 2.1.2 Shielding Versus EMC of the Product; 2.1.3 Grounding Versus EMC of the Product; 2.2 Analyses of Related Cases 2.2.1 Case 1: The Conducted Disturbance and the Grounding2.2.2 Case 2: The Ground Loop During the Conducted Emission Test; 2.2.3 Case 3: Where the Radiated Emission Outside the Shield Comes From; 2.2.4 Case 4: The "Floating" Metal and the Radiation; 2.2.5 Case 5: Radiated Emission Caused by the Bolt Extended Outside the Shield; 2.2.6 Case 6: The Compression Amount of the Shield and Its Shielding Effectiveness; 2.2.7 Case 7: The EMI Suppression Effectiveness of the Shielding Layer Between the Transformer's Primary Winding and Secondary Winding in the Switching-Mode Power Supply 2.2.8 Case 8: Bad Contact of the Metallic Casing and System Reset2.2.9 Case 9: ESD Discharge and the Screw; 2.2.10 Case 10: Heatsink Also Affects the ESD Immunity; 2.2.11 Case 11: How Grounding Benefits EMC Performance; 2.2.12 Case 12: The Heatsink Shape Affects Conducted Emissions from the Power Ports; 2.2.13 Case 13: The Metallic Casing Oppositely Causes the EMI Test Failed; 2.2.14 Case 14: Whether Directly Connecting the PCB Reference Ground to the Metallic Casing Will Lead to ESD 2.2.15 Case 15: How to Interconnect the Digital Ground and the Analog Ground in the Digital-Analog Mixed DevicesChapter 3 EMC Issues with Cables, Connectors, and Interface Circuits; 3.1 Introduction; 3.1.1 Cable Is the Weakest Link in the System; 3.1.2 The Interface Circuit Provides Solutions to the Cable Radiation Problem; 3.1.3 Connectors Are the Path Between the Interface Circuit and the Cable; 3.1.4 The Interconnection Between the PCBs Is the Weakest Link of the Product EMC; 3.2 Analyses of Related Cases; 3.2.1 Case 16: The Excessive Radiation Caused by the Cabling
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electromagnetic compatibility
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electromagnetic interference
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Books
952 ## - LOCATION AND ITEM INFORMATION (KOHA)
-- 5522
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Collection code Home library Current library Shelving location Date acquired Source of acquisition Cost, normal purchase price Inventory number Total Checkouts Full call number Barcode Date last seen Cost, replacement price Price effective from Currency Koha item type
    Dewey Decimal Classification     Non-fiction IIITDM Kurnool IIITDM Kurnool General Stacks 07.09.2022 Narendra Publishing House 72.00 NPH/22-23/IN-00121 DT 27/7/2022   621.38 ZHE 0004945 07.09.2022 72.00 07.09.2022 USD Books
LIBRARY HOURS
Mon - Sat : 9:00 AM - 5.30 PM
Library will remain closed on public holidays
Contact Us

Librarian
Central Libray
Indian Institute of Information Technology Design and Manufacturing Kurnool
Andhra Pradesh - 518 007

Library Email ID: library@iiitk.ac.in

Copyright @ Central Library | IIITDM Kurnool

Powered by Koha